11325232.04 01/2014 GB/D/F/E
14 WIKA operating instructions DiwiTherm
®
, model TR75
GB
4.1.3 DiwiTherm
®
for mounting on a pipe surface
Contact bulb
Material: stainless steel
Mounting tube: 120 mm
Fixing with a tightening strap (not included in delivery)
Cable
Silicone, shielded, application range -50 ... +200 °C
Cable length to user specications
The sensor sleeve and case are connected by the cable shielding. Earthing on both ends
can lead to potential losses and indication inaccuracy.
The specied accuracy can only be guaranteed up to a maximum cable length of 15 m. With
longer cable lengths, the accuracy can deviate sharply.
3157559.05
DiwiTherm
®
model TR75 for mounting on a pipe surface, rear cable output,
with panel mounting ange
Panel mounting
ange
4. Design and function