16 WIKA operating instructions pressure transmitter model O-10
GB
11613017.04 05/2013 GB/D/F/E
3. Specications
3.10 Operating conditions model O-10 (T)
Ingress protection (per IEC 60529)
For ingress protections see chapter 3.13 "Electrical connections model O-10 (T)"
The stated ingress protection only applies when plugged in using mating connectors that have the
appropriate ingress protection.
Vibration resistance (per IEC 60068-2-6)
20 g (20 ... 2,000 Hz, 120 min.)
Shock resistance (per IEC 60068-2-27)
40 g (6 ms), mechanical shock
Service life
10 million load cycles
Free fall test
Resistant to an impact onto concrete from 1 m
Temperatures
Medium: -30 ... +100 °C
Ambient: -30 ... +100 °C
Storage: -30 ... +100 °C