Fig. 2: Measures against moisture penetration
The ventilation for the electronics housing is realised via a lter
element in the vicinity of the cable glands.
Fig. 3: Position of the lter element with single and double chamber housing
1 Filter element for ventilation of the electronics housing
2 Blind stopper
Information:
Make sure that the lter element is always free of buildup during
operation. A high-pressure cleaner must not be used for cleaning.
Higher process temperatures mean often also higher ambient
temperatures.
Ventilation
Temperature limits
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor 4 20 mA 11
4 Mounting
37300-EN-100302