Use the seal corresponding to the instrument:
l Process tting GD: Tesnit seal in front of the thread
- or -
Seal the thread with teon, hemp or a similar resist ant seal material:
l Process tting GN
à Screw IPT-1* into the welded socket. Tighten the hexagon on the
process tting with a suitable wrench. Wrench size, see chapter
"Dimensional drawings".
Warning:
The housing must not be used to sc rew the instrument in! Applying
tightening force can damage internal parts of the housing.
Use the seal suitable for the respective process tting. You can nd
the components in the supplementary instructions manual "Welded
socket and seals".