Wika N-11 Manuel d'utilisateur Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 35
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
2147614.07 GB/D/F/E 04/2009
8
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11
2147614.07 GB/D/F/E 04/2009
9
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio N-10, N-11
7. Starting, operation
GB
Remove the protection cap by hand only just before installation and absolutely avoid
any damage to the diaphragm during installation as well (N-11).
For Model N-10 you have to provide for a sealing element; exceptions are instruments
with self-sealing threads (e.g. NPT thread).
For Model N-11 the sealing ring is included in delivery.
Please refer to our data sheet “Pressure gauge sealing washers AC 09.08” in WIKAs
product catalog Pressure and Temperature Measurement or our website
www.wika.de for details about sealing washers.
When mounting the instrument, ensure that the sealing faces of the instrument and
the measuring point are clean and undamaged.
Screw in or unscrew the instrument only via the flats using a suitable tool and the
prescribed torque. The appropriate torque depends on the dimension of the pressure
connection and on the sealing element used (form/material). Do not use the case as
working surface for screwing in or unscrewing the instrument.
When screwing the transmitter in, ensure that the threads are not jammed.
For tapped holes and welding sockets please see Technical Information IN 00.14 for
download at www.wika.de -Service
7. Starting, operation
GB
Electrical connection
Do not disconnect the electrical connection while under voltage!
Use a supply voltage with power limitation P W.
Ensure that the power supply is limited to U < 42 VDC even in the case of
malfunction.
Switch on the operating voltage only after establishing the electrical connec-
tion in order to avoid any spark formation.
Ground the cable screen at one end, preferably in the safe, thus non-
Ex, area (EN 60079-14). For transmitters with flying leads, the screen is
connected to the housing. The simultaneous connection of housing and
cable screen to ground is only permitted if ground loop problems between
the screen connection (e.g. at the power supply) and housing can be
excluded (see EN 60079-14).
Supply the pressure transmitter from a galvanically isolating power supply
unit.
Consider both the internal capacitance and inductance.
Cover flying leads with fine wires by an end splice (cable preparation).
Consider that cables for use in zones 20 and 22 must be checked with a test voltage
between conductor/earth, conductor/screen, screen/earth of more than 500V (AC).
An additional interlock,
to prevent the M12x1
connector from being
opened unintentionally, is
required. Use the attached
clip (WIKA part number
2073164). Put both parts
of the sleeve over the
connector shroud and
press them together to
secure it. Attach the flag to
the cable by inserting the
“arrow” into the hole.
For Transmitters with connector M12x1 and installation/use in Zone 22:
!
Warning
Warning
Warning
Warning
Vue de la page 4
1 2 3 4 5 6 7 8 9 10 ... 34 35

Commentaires sur ces manuels

Pas de commentaire

Philips EM1A manuals

Owner’s manuals and user’s guides for TVs & monitors Philips EM1A.
We providing 1 pdf manuals Philips EM1A for download free by document types: Specifications


Philips EM1A Specifications (54 pages)


Brand: Philips | Category: TVs & monitors | Size: 1.10 MB |

 




More products and manuals for TVs & monitors Philips

Models Document Type
27I REALFLAT CTV-DBX STEREO-REMOTE CONT 27RF50S99 Specifications   Philips 27I REALFLAT CTV-DBX STEREO-REMOTE CONT 27RF50S99 Specifications, 87 pages
32PFL5413D Specifications   Philips 32PFL5413D Specifications, 95 pages
BDP5600K User Manual   Benutzerhandbuch, 32 pages
34PW9815 Specifications   Philips 34PW9815 Specifications, 60 pages
32PF5321/12 User Manual   Leaflet 32PF5321_12 Released France (French [en] , 3 pages
32PFL3614/12 User Manual   www.philips.com/welcome [en] , 34 pages
37PFL7422/93 Specifications   Philips 37PFL7422/93 Specifications, 105 pages
32PW9576/12R Specifications   Philips 32PW9576/12R Specifications [en] , 118 pages
40HFL5573D/10 User Manual   www.philips.com/welcome, 78 pages
TC5.1L Specifications   Philips TC5.1L Specifications, 27 pages
LX3600D/17 User Manual   LX3600D LX3600D, 49 pages
19PS56C125 Service Manual   Philips 19PS56C125 Service manual, 79 pages
42PFL4606H/12 User Manual   Leaflet 42PFL4606H_12 Released Germany (German) High, 3 pages
HTB5570D User Manual   Manual do Usuário, 53 pages
26PF5521D/10 Specifications   Philips 26PF5521D/10 Specifications, 48 pages
21PT4457/58 User Manual   Va{iot prijatel vo digitalnata tehnologija, 16 pages
46PFL5606H User Manual   www.philips.com/welcome, 58 pages
26PFL3404D/12 User Manual   26PFL3404D/12 Philips LCD TV with Digital Crystal Clear, 3 pages
20RF50S Owner's Manual   Philips 20RF50S Owner`s manual, 125 pages
40PFL58x6D User Manual   Berlinale H2_Latam_78, 73 pages