11349167.03 10/2011 GB/D/F/E
WIKA operating instructions intelliGAUGE / switchGAUGE
Contents of
tailpipe
Typically
Liquid media Gaseous media
Liquid Liquid
with
vapour
Vapour
only
Gas only Wet gas Liquid
gas con-
densate
Conden-
sate
Boiling
liquid
Liqueed
gas
Dry air Moist air,
Flue gas
Steam
Pressure
instrument
higher than
tapping point
Pressure in-
strument lower
than tapping
point
7
GB
4. Installation and commissioning / 5. Measuring arrangements
If the pressure transmitter is positioned lower than the pressure test
connection, the tailpipe has to be rinsed thoroughly prior to tting the gauge
to remove all foreign substances.
Once the pressure and electrical connections have been made, the trans-
mitter is ready for immediate use.
Before dismounting the pressure instrument the measuring element has to
be depressurized. Eventually the stress of the pipe has to be relieved.
Residual pressure medium remaining within the pressure
element may cause harm to men, facilities and environment.
Therefore sucient precautionary measures have to be
taken.
Pressure connector
In accordance with the general technical regulations for pressure gauges
(e.g. EN 837-2 „Selection and installation recommendations for pressure
gauges“).
5. Measuring arrangements
Proven measuring arrangements for various types of media.
Installation using
a spanner