Wika WUD-26 Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
11611057.01 GB/D 11/2013
13
Operating instructions/Betriebsanleitung, WUD-2x
Specications Models WUD-20, WUD-25 and WUD-26
Permissible temperature of
Medium -20 ... +100 °C / -4 ... +212 °F
Ambience -10 ... +60 °C / 14 ... 140 °F
Storage -10 ... +60 °C / 14 ... 140 °F
Rated temperature range -20 ... +80 °C / -4 ... +176 °F (active compensated)
Temperature coecients within
rated temperature range
(active compensated)
Mean TC of zero
0.10 % of span / 10 K
Mean TC of range
0.15 % of span / 10 K
RoHS-conformity Yes
CE- conformitiy
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (industrial locations)
Assembly and packing area Clean room class 5 according to ISO 14644
Packaging Double bagging according to SEMI E49.6
Shock resistance 15 g (11 ms); 30 g (6 ms)
Vibration resistane 7.5 mm or 2 g (1 ... 200 Hz) / 5 g
Wiring protection
Short-circuit proofness S
+
towards U
-
Reverse polarity protection U
+
towards U-
Weight Approx. 0.2 kg
7. Initial start-up and operation
When designing your plant, take into account that the stated values (e.g.burst pressure, over pressure safety)
apply depending on the material, thread and sealing element used.
GB