17WIKA operating instructions level switch model LSD-30
GB
11613033.01 01/2012 GB/D/F/E
Seal
Correct sealing of the process connections with parallel threads at the sealing
face
must be made using suitable at gaskets, sealing rings or WIKA prole
sealings. The sealing of tapered threads (e.g. NPT threads) is made by providing
the thread with additional sealing material such as, for example, PTFE tape (EN
837-2).
For further information on seals see WIKA data sheet AC 09.08 or under www.wika.com.
Pin assignment
6. Commissioning, operation
Circular connector M12 x 1, 4-pin
Assignment
U+ U
-
S+ SP1 SP2
1 3 2 4 2
Circular connector M12 x 1, 5-pin
Assignment
U+ U
-
S+ SP1 SP2
1 3 5 4 2