4. Design and function
4.1 Description
The temperature transmitter is used for converting a resistance value
or a voltage value into a proportional current signal (4 ... 20 mA).
Thus the sensors are permanently monitored for their fault-free
operation.
The transmitter meets the requirements for:
Functional safety per IEC 61508/IEC 61511-1 (depending on the
version)
Explosion protection (depending on the version)
Electromagnetic compatibility in accordance with NAMUR
recommendation NE21
Signalling at the analogue output in accordance with NAMUR
recommendation NE43
Sensor burnout signalling in accordance with NAMUR
recommendation NE89 (corrosion monitoring sensor connection)
4.2 Operation in safety-related applications
The model T32.xS.xxx-S (SIL version) has been
designed for use in safety-related applications.
The marking of this design variant is given in chapter 2.6 “Labelling,
safety marking”. For operation in safety-related applications the
additional requirements must be observed (see safety manual
“Information on functional safety of model T32.xS”). The instructions
contained in this must be followed without fail.
4.3 Scope of delivery
Cross-check scope of delivery with delivery note.