Parallel thread Tapered thread
10 WIKA operating instructions temperature switch model TSD-30
GB
11613025.02 12/2011 GB/D/F/E
3. Specications
Analogue signal
Load
Current: ≤ 500 Ω
Voltage: > 10 kΩ
Switching output
Switching output 1 and 2 are individually adjustable
Function
Normally open/closed: freely adjustable
Window and hysteresis: freely adjustable
Switching voltage: Power supply – 1 V
Switching current: max. 250 mA per switching output
Response time ≤ 200 ms
Adjustment accuracy:
≤ 0.5 % of span
3.4 Power supply
Power supply
DC 15 ... 35 V
Current consumption
max. 100 mA
Total current consumption
max. 600 mA (incl. switching current)
3.5 Measuring element
Pt1000, 2-wire, DIN EN 60751 / class A
Insertion length (F)
F in mm
25 50 100 150 250 350
Fig. Insertion length (F)